Andere Anwendungen und OEM's |
RADOX EN 50306 300/500 V M Halogen free, electron- beam cross- linked cables with improved behaviour in case of fire, easy to strip and flexible. |
Cu |
5 |
300/500 V |
|
120 °C |
low smoke fire retardant zero halogen |
RADOX EN 50306 300/500 V MM S Screened halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. |
Cu |
5 |
300/500 V |
|
120 °C |
low smoke zero halogen flame retardent |
RADOX 3 GKW EN 50264 0,6/1 kV M Halogen free, electron- beam cross- linked cables with improved behaviour in case of fire, easy to strip and flexible. |
Cu |
5 |
0,6/1 kV |
|
120 °C |
low smoke fire retardant zero halogen |
RADOX TENUIS TW EN 50306 0,6/1 kV M Halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. |
Cu |
5 |
0,6/1 kV |
|
120 °C |
low smoke zero halogen flame retardent |
RADOX TENUIS TW EN 50306 0,6/1 kV MM Halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. |
Cu |
5 |
0,6/1 kV |
|
120 °C |
low smoke zero halogen flame retardent |
RADOX TENUIS TW EN 50306 0,6/1 kV MM S Screened halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. |
Cu |
5 |
0,6/1 kV |
|
120 °C |
low smoke zero halogen flame retardent |
RADOX GKW LW EN 50306 0,6/1 kV M Halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. |
Cu |
5 |
0,6/1 kV |
|
120 °C |
low smoke zero halogen flame retardent |
RADOX GKW LW EN 50306 0,6/1 kV MM Halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. |
Cu |
5 |
0,6/1 kV |
|
120 °C |
low smoke zero halogen flame retardent |
RADOX GKW LW EN 50306 0,6/1 kV MM S Screened halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. |
Cu |
5 |
0,6/1 kV |
|
120 °C |
low smoke zero halogen flame retardent |
RADOX 4 GKW EN 50264 1,8/3 kV M Halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. |
Cu |
5 |
1,8/3 kV |
|
120 °C |
low smoke zero halogen flame retardent |
RADOX 4 GKW EN 50264 1,8/3 kV MM Halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. |
Cu |
5 |
1,8/3 kV |
|
120 °C |
low smoke zero halogen flame retardent |
RADOX RAILDAT 120 Ohm 0,75 mm² XM S Halogenfree electron beam cross linked data cable with improved behaviour in case of fire. |
Cu |
5 |
100 V |
|
90 °C |
|
RADOX RAILDAT 120 Ohm 0,5 mm² XM S Halogenfree electron beam cross linked data cable with improved behaviour in case of fire. |
Cu |
5 |
100 V |
|
90 °C |
|
RADOX 4 GKW EN 50264 1,8/3 kV MM S Screened, halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. |
Cu |
5 |
1,8/3 kV |
|
120 °C |
low smoke zero halogen flame retardent |
RADOX 9 GKW EN 50264 3,6/6 kV M Halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. |
Cu |
5 |
3,6/6 kV |
|
120 °C |
low smoke zero halogen flame retardent |
RADOX 9 GKW EN 50264 3,6/6 kV MM S Screened, halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. |
Cu |
5 |
3,6/6 kV |
|
120 °C |
low smoke zero halogen flame retardent |
RADOX 155 Battery Cable Power and Battery cable, for use in road vehicle applications. |
Cu |
5 |
0,6/1 kV |
|
150 °C |
flame retardent |
RADOX Elastomer S Battery Cable Power and Battery cable, for use in road vehicle applications. |
Cu |
5 |
0,6/1 kV |
|
150 °C |
flame retardent |
RADOX AUTO B screened, single core Cable, for use in road vehicle applications. |
Cu |
5 |
0,6/1 kV |
|
150 °C |
flame retardent |
RADOX 125 Electron beam crosslinked Isolation; excellent high temperature, low temperature, ozone, weathering and abrasion resistance. |
Cu |
5 |
0,6/1 kV |
Eca |
125 °C |
low smoke fire retardant zero halogen |
RADOX 155 Electron beam crosslinked Isolation; excellent high temperature, low temperature, ozone, weathering and abrasion resistance. |
Cu |
5 |
0,6/1 kV |
|
155 °C |
|
RADOX UL 3271 Excellent high temperature, low temperature, ozone and weathering resistance, flame retardant, easy to strip and process, heat pressure and highly abrasion resistant, soldering iron resistant, flexible. |
Cu |
5 |
0,6/1 kV |
|
125 °C |
flame retardent |
RADOX UL 3289 Excellent high temperature, low temperature, ozone and weathering resistance, flame retardant, soldering iron resistant, easy to strip and process, compatible to all common resins and varnishes, flexible. |
Cu |
5 |
0,6/1 kV |
|
150 °C |
flame retardent |
RADOX Oil & Gaz The products feature exceptional performance, quality and durability. They ensure the reliable transmission of energy, signals and data even in demanding outdoor conditions. |
Cu |
5 |
|
|
|
|
Twinflex Battery Cable Flexible battery connection cable for indoors and outdoors. |
Cu |
6 |
450/750 V |
|
70 °C |
flame retardent |
YSLY/LIYY PVC halogen control cable with improved fire characteristics for various applications. |
Cu |
5 |
300/500 V |
Cca |
70 °C |
fire retardant |
YSLCY/LIYCY Screened PVC control cable with improved fire characteristics for various applications. |
Cu |
5 |
300/500 V |
Cca |
70 °C |
fire retardant |
YSLY 1 kV Flexible power, process control and instrumentation cable with inner sheath. |
Cu |
5 |
0,6/1 kV |
Eca |
70 °C |
flame retardent |
YSLYCY 1 kV Flexible and screened power, process control and instrumentation cable with inner sheath. |
Cu |
5 |
0,6/1 kV |
Eca |
70 °C |
flame retardent |
HSLH UV Cca UV resistant zero halogen control cable with improved fire characteristics for various applications. |
Cu |
5 |
300/500 V |
Cca |
70 °C |
fire retardant low smoke zero halogen |
HSLH/LIHH Cca Zero halogen control cable with improved fire characteristics for various applications. |
Cu |
5 |
300/500 V |
Cca |
70 °C |
fire retardant low smoke zero halogen |
HSLCH UV Cca UV resistant zero halogen screened control cable with improved fire characteristics for various applications. |
Cu |
5 |
300/500 V |
Cca |
70 °C |
fire retardant low smoke zero halogen |
HSLCH/LIHCH Cca Zero halogen screened control cable with improved fire characteristics for various applications. |
Cu |
5 |
300/500 V |
Cca |
70 °C |
fire retardant low smoke zero halogen |
Compensation and Thermocouple Compensating and thermocouple extension cables are used for temperature sensing in industrial processes. |
|
1, 2, 5 |
|
|
|
|
SiD (SiA) Single core with silicone insulation. |
Cu |
1 |
300/500 V |
|
180 °C |
|
SiF Flexible single core with silicone insulation. |
Cu |
5 |
300/500 V |
|
180 °C |
|
H05V-K Harmonised single core for fixed and protected installation in devices, control cabinets and in or on lighting equipment. |
Cu |
5 |
300/500 V |
Eca |
70 °C |
flame retardent |
H07V-K Harmonised single core for fixed and protected installation in devices, control cabinets and in or on lighting equipment. |
Cu |
5 |
450/750 V |
Eca |
70 °C |
flame retardent |
H05Z-K Harmonised, zero halogen single core for internal wiring. |
Cu |
5 |
300/500 V |
Eca |
90 °C |
flame retardent |
H07Z-K Harmonised, zero halogen single core for internal wiring. |
Cu |
5 |
450/750 V |
Eca |
90 °C |
flame retardent |
H07Z1-K Harmonised, zero halogen single core with improved fire characteristics for internal wiring. |
Cu |
5 |
450/750 V |
Cca, B2ca |
70 °C |
zero halogen flame retardent low smoke |
H05V2-K Tri rated Multi-standard, heat resistant single core for internal wiring. |
Cu |
5 |
450/750 V |
Eca |
90 °C |
flame retardent |
H07V2-K Tri rated Multi-standard, heat resistant single core for internal wiring. |
Cu |
5 |
450/750 V |
Eca |
90 °C |
flame retardent |
H07RN-F Rubber-sheated flexible cable. |
Cu |
5 |
450/750 V |
Eca |
60 °C |
flame retardent |
H07RN-F 90°C Premium Rubber-sheathed, flexible cable. |
Cu |
5 |
450/750 V |
Eca |
90 °C |
flame retardent |
H07ZZ-F Zero halogen rubber-sheated flexible cable. |
Cu |
5 |
450/750 V |
Cca |
90 °C |
low smoke zero halogen fire retardant |
NSSHOEU /3E Heavy-duty, rubber cable for fixed and flexible operations as power supply cable. |
Cu |
5 |
0,6/1 kV |
|
90 °C |
|
NSSHOEU Heavy-duty, rubber-sheated flexible cable. |
Cu |
5 |
0,6/1 kV |
|
90 °C |
|
H01N2-D Rubber-sheated flexible arc welding cable. |
Cu |
6 |
100 V |
|
85 °C |
flame retardent |
NSGAFöu Rubber-sheated flexible cable. |
Cu |
5 |
1,8/3 kV |
Eca |
90 °C |
flame retardent |