Andere Anwendungen und OEM's |
RADOX 3 GKW EN 50264 0,6/1 kV M Halogen free, electron- beam cross- linked cables with improved behaviour in case of fire, easy to strip and flexible. | Cu | 5 | 0,6/1 kV | | 120 °C | low smoke fire retardant zero halogen |
RADOX 3 GKW EN 50264 0,6/1 kV MM Halogen free, electron- beam cross- linked cables with improved behaviour in case of fire, easy to strip and flexible. | Cu | 5 | 0,6/1 kV | | 120 °C | low smoke fire retardant zero halogen |
RADOX 3 GKW EN 50264 0,6/1 kV MM S Screened halogen free, electron- beam cross- linked cables with improved behaviour in case of fire, easy to strip and flexible. | Cu | 5 | 0,6/1 kV | | 120 °C | low smoke fire retardant zero halogen |
RADOX TENUIS TW EN 50306 0,6/1 kV M Halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. | Cu | 5 | 0,6/1 kV | | 120 °C | low smoke zero halogen flame retardent |
RADOX TENUIS TW EN 50306 0,6/1 kV MM Halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. | Cu | 5 | 0,6/1 kV | | 120 °C | low smoke zero halogen flame retardent |
RADOX TENUIS TW EN 50306 0,6/1 kV MM S Screened halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. | Cu | 5 | 0,6/1 kV | | 120 °C | low smoke zero halogen flame retardent |
RADOX GKW LW EN 50306 0,6/1 kV M Halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. | Cu | 5 | 0,6/1 kV | | 120 °C | low smoke zero halogen flame retardent |
RADOX GKW LW EN 50306 0,6/1 kV MM Halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. | Cu | 5 | 0,6/1 kV | | 120 °C | low smoke zero halogen flame retardent |
RADOX GKW LW EN 50306 0,6/1 kV MM S Screened halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. | Cu | 5 | 0,6/1 kV | | 120 °C | low smoke zero halogen flame retardent |
RADOX EN 50306 300/500 V M Halogen free, electron- beam cross- linked cables with improved behaviour in case of fire, easy to strip and flexible. | Cu | 5 | 300/500 V | | 120 °C | low smoke fire retardant zero halogen |
RADOX EN 50306-4-1P 300/500 V MM Halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. | Cu | 5 | 300/500 V | | 120 °C | low smoke zero halogen flame retardent |
RADOX EN 50306-4-1E 300/500 V MM Halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. | Cu | 5 | 300/500 V | | 120 °C | low smoke zero halogen flame retardent |
RADOX EN 50306-4 3P 5E 5P 5E 7P 7E 300/500 V MM S Screened halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. | Cu | 5 | 300/500 V | | 120 °C | low smoke zero halogen flame retardent |
RADOX 4 GKW EN 50264 1,8/3 kV M Halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. | Cu | 5 | 1,8/3 kV | | 120 °C | low smoke zero halogen flame retardent |
RADOX 4 GKW EN 50264 1,8/3 kV MM Halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. | Cu | 5 | 1,8/3 kV | | 120 °C | low smoke zero halogen flame retardent |
RADOX 4 GKW EN 50264 1,8/3 kV MM S Screened, halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. | Cu | 5 | 1,8/3 kV | | 120 °C | low smoke zero halogen flame retardent |
RADOX 9 GKW EN 50264 3,6/6 kV MM S Screened, halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. | Cu | 5 | 3,6/6 kV | | 120 °C | low smoke zero halogen flame retardent |
RADOX RAILDAT 120 Ohm 0,5 mm² XM S Halogenfree electron beam cross linked data cable with improved behaviour in case of fire. | Cu | 5 | 100 V | | 90 °C | |
RADOX RAILDAT 120 Ohm 0,75 mm² XM S Halogenfree electron beam cross linked data cable with improved behaviour in case of fire. | Cu | 5 | 100 V | | 90 °C | |
RADOX 155 Battery Cable Power and Battery cable, for use in road vehicle applications. | Cu | 5 | 0,6/1 kV | | 150 °C | flame retardent |
RADOX Elastomer S Battery Cable Power and Battery cable, for use in road vehicle applications. | Cu | 5 | 0,6/1 kV | | 150 °C | flame retardent |
RADOX AUTO B screened, single core Cable, for use in road vehicle applications. | Cu | 5 | 0,6/1 kV | | 150 °C | flame retardent |
RADOX 125 Electron beam crosslinked Isolation; excellent high temperature, low temperature, ozone, weathering and abrasion resistance. | Cu | 5 | 0,6/1 kV | Eca | 125 °C | low smoke fire retardant zero halogen |
RADOX 155 Electron beam crosslinked Isolation; excellent high temperature, low temperature, ozone, weathering and abrasion resistance. | Cu | 5 | 0,6/1 kV | | 155 °C | |
RADOX UL 3271 Excellent high temperature, low temperature, ozone and weathering resistance, flame retardant, easy to strip and process, heat pressure and highly abrasion resistant, soldering iron resistant, flexible. | Cu | 5 | 0,6/1 kV | | 125 °C | flame retardent |
RADOX UL 3289 Excellent high temperature, low temperature, ozone and weathering resistance, flame retardant, soldering iron resistant, easy to strip and process, compatible to all common resins and varnishes, flexible. | Cu | 5 | 0,6/1 kV | | 150 °C | flame retardent |
RADOX Oil & Gaz The products feature exceptional performance, quality and durability. They ensure the reliable transmission of energy, signals and data even in demanding outdoor conditions. | Cu | 5 | | | | |
Twinflex Battery Cable Flexible battery connection cable for indoors and outdoors. | Cu | 6 | 450/750 V | | 70 °C | flame retardent |
YSLY/LIYY PVC halogen control cable with improved fire characteristics for various applications. | Cu | 5 | 300/500 V | Cca | 70 °C | fire retardant |
YSLCY/LIYCY Screened PVC control cable with improved fire characteristics for various applications. | Cu | 5 | 300/500 V | Cca | 70 °C | fire retardant |
YSLY 1 kV Flexible power, process control and instrumentation cable with inner sheath. | Cu | 5 | 0,6/1 kV | Eca | 70 °C | flame retardent |
YSLYCY 1 kV Flexible and screened power, process control and instrumentation cable with inner sheath. | Cu | 5 | 0,6/1 kV | Eca | 70 °C | flame retardent |
HSLH UV Cca UV resistant zero halogen control cable with improved fire characteristics for various applications. | Cu | 5 | 300/500 V | Cca | 70 °C | fire retardant low smoke zero halogen |
HSLH/LIHH Cca Zero halogen control cable with improved fire characteristics for various applications. | Cu | 5 | 300/500 V | Cca | 70 °C | fire retardant low smoke zero halogen |
HSLCH UV Cca UV resistant zero halogen screened control cable with improved fire characteristics for various applications. | Cu | 5 | 300/500 V | Cca | 70 °C | fire retardant low smoke zero halogen |
HSLCH/LIHCH Cca Zero halogen screened control cable with improved fire characteristics for various applications. | Cu | 5 | 300/500 V | Cca | 70 °C | fire retardant low smoke zero halogen |
Compensation and Thermocouple Compensating and thermocouple extension cables are used for temperature sensing in industrial processes. | | 1, 2, 5 | | | | |
SiD (SiA) Single core with silicone insulation. | Cu | 1 | 300/500 V | | 180 °C | |
SiF Flexible single core with silicone insulation. | Cu | 5 | 300/500 V | | 180 °C | |
H05V-K Harmonised single core for fixed and protected installation in devices, control cabinets and in or on lighting equipment. | Cu | 5 | 300/500 V | Eca | 70 °C | flame retardent |
H07V-K Harmonised single core for fixed and protected installation in devices, control cabinets and in or on lighting equipment. | Cu | 5 | 450/750 V | Eca | 70 °C | flame retardent |
H05Z-K Harmonised, zero halogen single core for internal wiring. | Cu | 5 | 300/500 V | Eca | 90 °C | flame retardent |
H07Z-K Harmonised, zero halogen single core for internal wiring. | Cu | 5 | 450/750 V | Eca | 90 °C | flame retardent |
H07Z1-K Harmonised, zero halogen single core with improved fire characteristics for internal wiring. | Cu | 5 | 450/750 V | Cca, B2ca | 70 °C | zero halogen flame retardent low smoke |
H05V2-K Tri rated Multi-standard, heat resistant single core for internal wiring. | Cu | 5 | 450/750 V | Eca | 90 °C | flame retardent |
H07V2-K Tri rated Multi-standard, heat resistant single core for internal wiring. | Cu | 5 | 450/750 V | Eca | 90 °C | flame retardent |
H07RN-F Rubber-sheated flexible cable. | Cu | 5 | 450/750 V | Eca | 60 °C | flame retardent |
H07RN-F 90°C Premium Rubber-sheathed, flexible cable. | Cu | 5 | 450/750 V | Eca | 90 °C | flame retardent |
H07ZZ-F Zero halogen rubber-sheated flexible cable. | Cu | 5 | 450/750 V | Cca | 90 °C | low smoke zero halogen fire retardant |
NSSHOEU /3E Heavy-duty, rubber cable for fixed and flexible operations as power supply cable. | Cu | 5 | 0,6/1 kV | | 90 °C | |
NSSHOEU Heavy-duty, rubber-sheated flexible cable. | Cu | 5 | 0,6/1 kV | | 90 °C | |
H01N2-D Rubber-sheated flexible arc welding cable. | Cu | 6 | 100 V | | 85 °C | flame retardent |
NSGAFöu Rubber-sheated flexible cable. | Cu | 5 | 1,8/3 kV | Eca | 90 °C | flame retardent |