Gebäudetechnik und Anlagenbau |
VVT PVC installation cable with improved fire characteristics for telecommunications and information processing systems. | Cu | 1 | 150 V | Cca | 70 °C | fire retardant |
TPVF PVC telecommunication cable with improved fire characteristics for fixed installation. | Cu | 1 | 250 V | Cca | 70 °C | fire retardant |
TPGF Halogen-free telecommunication cable with improved fire characteristics for fixed installation. | Cu | 1 | 250 V | Cca | 70 °C | fire retardant |
GGT Zero halogen installation cable with improved fire characteristics for telecommunications and information processing systems. | Cu | 1 | 150 V | Cca | 70 °C | fire retardant |
U/UTP LSOH Cca Zero halogen and fire retardant data transmission cable for frequencies up to 250 MHz for use installation in generic cabling systems. Ideal for all applications of class D up to E. For fixed installation indoors. | Cu | 1 | | B2ca | 70 °C | fire retardant zero halogen |
S/FTP Cca PiMF, Cat7 Data transmission cable with individual and collective screen, zero halogen, fire retradant. | Cu | 1 | | Cca | 70 °C | fire resistant zero halogen |
S/FTP Cat7a Cca Rodent resistant Data transmission cable with individual and collective screen, zero halogen, fire retardant, with rodent protection. | Cu | 1 | | Cca | 70 °C | zero halogen fire retardant |
S/FTP Fca 2Y, Cat7 Data transmission cable with individual and collective screen, zero halogen, UV resistant. | Cu | | | Fca | 70 °C | zero halogen |
Z1O-J-H(St)H Collectively screened, zero halogen and armoured installation cable with improved fire characteristics. | Cu | 1 | 300 V | Cca | 70 °C | low smoke zero halogen fire retardant |
HCHM EIB Collectively screened communication cable with improved fire characteristics for telecommunications and information processing systems. | Cu | 1 | 250 V | Cca | 70 °C | fire retardant |
A-DQ(ZN)B2Y Outdoor fiber optic cable with central loose tube and non-metallic rodent protection. | | | | | 70 °C | |
A-DQ(ZN)(SR)2Y unitube Outdoor fiber optic cable with central loose tube and metallic rodent protection. | | | | | 70 °C | |
A-DQ(ZN)(SR)2Y multitube Outdoor fiber optic cable with central loose tube and metallic rodent protection. | | | | | 70 °C | |
A-DQ(ZN)BHMHBY-fl Lead sheathed, halogen free fibre optic outdoor cable with improved fire characteristics. | | | | | 60 °C | fire retardant |
JE-Y(St)Y Bd Industrial electronic cable for transmission of signals and measurements. | Cu | 1 | 225 V | Eca | 70 °C | flame retardent |
LIHCH DIN 47100 Halogen-free and environmentally data transmission cable, control and connecting cable. | Cu | 5 | 250 V | Cca | 70 °C | fire retardant low smoke zero halogen |
LIHCH TP DIN 47100 Halogen-free and environmentally data transmission cable, control and connecting cable. | Cu | 5 | 250 V | Cca | 70 °C | fire retardant low smoke zero halogen |
Li2YCY/Li2YCYv Signal-, control- and measuring cable for transmission of low, sensitive signals and high bit rates. | Cu | 2 | 250 V | Eca | 70 °C | flame retardent |
YSLY/LIYY PVC halogen control cable with improved fire characteristics for various applications. | Cu | 5 | 300/500 V | Cca | 70 °C | fire retardant |
YSLCY/LIYCY Screened PVC control cable with improved fire characteristics for various applications. | Cu | 5 | 300/500 V | Cca | 70 °C | fire retardant |
YSLY 1 kV Flexible power, process control and instrumentation cable with inner sheath. | Cu | 5 | 0,6/1 kV | Eca | 70 °C | flame retardent |
YSLYCY 1 kV Flexible and screened power, process control and instrumentation cable with inner sheath. | Cu | 5 | 0,6/1 kV | Eca | 70 °C | flame retardent |
LIYCY-J Cca, 1 kV Flexible collectively screened control cable with improved fire characteristics for various applications. | Cu | 5 | 0,6/1 kV | Cca | 90 °C | fire retardant zero halogen |
YSLYQY/LIYYSY Steel wire-reinforced, universal measurement and control cable. | Cu | 5 | 300/500 V | Eca | 70 °C | flame retardent |
HSLH/LIHH Zero halogen control cable with improved fire characteristics for various applications. | Cu | 5 | 300/500 V | Cca | 70 °C | fire retardant |
HSLCH/LIHCH Zero halogen screened control cable with improved fire characteristics for various applications. | Cu | 5 | 300/500 V | Cca | 70 °C | fire retardant |
2XSL(St)CYK-J Flexible motor power supply cable with improved fire characteristics for frequency converter. | Cu | 5 | 0,6/1 kV | Cca | 90 °C | fire retardant |
Li-2XY(CuB)CY-J Flexible motor power supply cable with improved fire characteristics for frequency converter. | Cu | 5 | 0,6/1 kV | Cca | 90 °C | fire retardant |
ROZ1-K Flexible zero halogen motor power supply cable with improved fire characteristics for frequency converter. | Cu | 5 | 0,6/1 kV | Cca | 90 °C | fire retardant |
Compensation and Thermocouple Compensating and thermocouple extension cables are used for temperature sensing in industrial processes. | | 1, 2, 5 | | | | |
SIF GL Flexible silicone single core with glass fibre braid. | Cu | 5 | 300/500 V | | 180 °C | |
(N)HXH E30 Fire resistant power cable. Cables with intrinsic fire resistance | Cu | 1, 2 | 0,6/1 kV | | 90 °C | fire resistant |
(N)HXCH E30 Fire resistant power cable with concentric copper conductor. Cables with intrinsic fire resistance. | Cu | 1, 2 | 0,6/1 kV | | 90 °C | fire resistant |
(N)HXH E90 Fire resistant power cable. Cables with intrinsic fire resistance. | Cu | 1, 2 | 0,6/1 kV | | 90 °C | |
(N)HXCH E90 Fire resistant power cable with concentric copper conductor. Cables with intrinsic fire resistance. | Cu | 1, 2 | 0,6/1 kV | | 90 °C | fire resistant |
Fire Resistant RF 1h30 Fire resistant power cable. Cables with intrinsic fire resistance. | Cu | 1, 2 | 450/750 V | | 70 °C | |
XVB NBN Installation cable with improved fire characteristics for various industrial and domestic applications. | Cu | 1, 2 | 0,6/1 kV | Cca | 90 °C | fire retardant |
XV flex Flexible single core power cable with improved fire characteristics for fixed installations. | Cu | 5 | 0,6/1 kV | Cca | 90 °C | flame retardent |
EXVB NBN Power cable with reinforced sheath for domestic or industrial application. | Cu | 1, 2 | 0,6/1 kV | Eca | 90 °C | flame retardent |
EXAVB NBN Armoured power cable with improved fire characteristics for domestic or industrial application. | Cu | 1, 2 | 0,6/1 kV | Cca | 90 °C | fire retardant |
SXAVB NBN Armoured signalling and control cable with improved fire characteristics. | Cu | 1 | 0,6/1 kV | Cca | 90 °C | fire retardant |
XFVB NBN Armoured signalling and control cable with improved fire characteristics | Cu | 1, 2 | 0,6/1 kV | Cca | 90 °C | fire retardant |
EAXeVB NBN Power cable with aluminium conductor. | Alu | 1, 2 | 0,6/1 kV | Eca | 90 °C | flame retardent |
XGB NBN Zero halogen installation cable with improved fire characteristics for various industrial and domestic applications. | Cu | 1, 2 | 0,6/1 kV | Cca | 90 °C | zero halogen low smoke fire retardant |
EAXG Zero halogen installation cable with improved fire characteristics for various industrial and domestic applications where no mechanical damage is to be expected. | Alu | 1, 2 | 0,6/1 kV | | 90 °C | fire retardant zero halogen |
NYY VDE Power and control cable. For fixed installation indoors and outdoors. | Cu | 1, 2 | 0,6/1 kV | Eca | 70 °C | flame retardent |
NYCY VDE Power and control cable with concentric copper conductor. | Cu | 1 | 0,6/1 kV | Eca | 70 °C | flame retardent |
NYCWY VDE Power and control cable with concentric copper conductor. | Cu | 2 | 0,6/1 kV | Eca | 70 °C | flame retardent |
NAYY VDE Power and control cable with aluminium conductor. | Alu | 1, 2 | 0,6/1 kV | Eca | 70 °C | flame retardent |
E-AYY ÖVE Power and control cable with aluminium conductor. | Alu | 1, 2 | 0,6/1 kV | Eca | 70 °C | flame retardent |
NAYCWY VDE Power cable with aluminium conductor and concentric copper conductor. | Alu | 1, 2 | 0,6/1 kV | Eca | 70 °C | flame retardent |
NHXMH VDE Zero halogen installation cable with improved fire characteristics for various industrial and domestic applications. | Cu | 1, 2 | 300/500 V | Dca, Eca | 70 °C | low smoke zero halogen fire retardant |
N2XH Zero halogen power cable with copper conductor and improved fire characteristics. | Cu | 1, 2 | 0,6/1 kV | Cca, B2ca | 90 °C | low smoke zero halogen fire retardant |
N2XCH Zero halogen power cable with concentric copper conductor and improved fire characteristics. | Cu | 1, 2 | 0,6/1 kV | Cca, B2ca | 90 °C | zero halogen low smoke fire retardant |
N2XH flex Flexible and halogen-free power and control cable with improved fire characteristics for fixed. | Cu | 5 | 0,6/1 kV | B2ca, Cca | 90 °C | fire retardant low smoke zero halogen |
YMVK flex Flexible single core power cable with improved fire characteristics for fixed installations. | Cu | 5 | 0,6/1 kV | Eca | 90 °C | fire retardant |
YMz1K NEN Zero halogen installation cable with improved fire characteristics for various industrial and domestic application. | Cu | 1, 2 | 0,6/1 kV | B2ca | 90 °C | low smoke zero halogen fire retardant |
RV-K Flexible power and control cable for fixed installations in industrial or domestic environment and public buildings. | Cu | 5 | 0,6/1 kV | Eca | 90 °C | flame retardent |
RZ1-K (AS) Flexible and halogen-free power and control cable with improved fire characteristics for fixed installations in industrial or domestic environment and public buildings. | Cu | 5 | 0,6/1 kV | Cca, B2ca | 90 °C | low smoke zero halogen fire retardant |
RZ1 (AS) AL Zero halogen aluminium power cable with improved fire characteristics for fixed installation. | Alu | 2 | 0,6/1 kV | B2ca, Cca | 90 °C | low smoke zero halogen fire retardant |
RZ1MZ1-K Armoured, zero halogen installation cable with improved fire characteristics for domestic and industrial application. | Cu | 5 | 0,6/1 kV | Cca | 90 °C | low smoke zero halogen fire retardant |
U1000 R2V NFC Power, control and installation cable for domestic or industrial application. | Cu | 1, 2 | 0,6/1 kV | Eca | 90 °C | flame retardent |
U1000 RGPFV Lead sheathed, steel tape armoured and hydrocarbon resistant power cable with improved fire characteristics | Cu | 1, 2 | 0,6/1 kV | | 90 °C | fire retardant |
XLPE/LSZH/AWA/LSZH BS Armoured, zero halogen power cable with improved fire characteristics. | Cu | 1, 2 | 0,6/1 kV | Cca, Dca | 90 °C | fire retardant low smoke zero halogen |
XLPE/LSZH/SWA/LSZH BS Armoured, zero halogen power cable with improved fire characteristics. | Cu | | 0,6/1 kV | Cca | 90 °C | low smoke zero halogen fire retardant |
ESUY earthing conductor Highly flexible single core conductor for use in portable earthing and short circuit-devices. | Cu | 6 | | | 70 °C | flame retardent |
Bare copper conductor For use in electrical grounding systems, on insulators for overhead transmission and distribution applications. | | 1, 2 | | | | |
EXeCVB IEC 60332-3-24 NBN Medium voltage cable with improved fire characteristics for power stations, industrial applications and distribution networks | Cu | 2 | 8,7/15 kV | | 90 °C | fire retardant |
EAXeCWB NBN Medium voltage cable with reduced insulation thickness for power stations, industrial applications and distribution networks | Alu | 2 | 8,7/15 kV | | 90 °C | |
BAXeCWB NBN medium voltage cable with reduced insulation thickness for power stations, industrial applications and distribution networks. | Alu | 2 | 8,7/15 kV | | 90 °C | |
EAXeCWB 36 kV NBN Medium voltage cable with reduced insulation thickness for power stations, industrial applications and distribution networks. | Alu | 2 | 8,7/15 kV, 12/20 kV, 18/30 kV or 20,8/36 kV | | 90 °C | |
N2XSY VDE Medium voltage cable for power stations, industrial applications and distribution networks. | Cu | 2 | 6/10 kV, 12/20 kV or 18/30 kV | | 90 °C | flame retardent |
N2XS(F)2Y VDE Medium voltage cable for power stations, industrial applications and distribution networks. | Cu | 2 | 6/10 kV, 12/20 kV or 18/30 kV | | 90 °C | |
NA2XS(F)2Y VDE Medium voltage cable for power stations, industrial applications and distribution networks. | Alu | 2 | 6/10 kV, 12/20 kV or 18/30 kV | | 90 °C | |
N2XSEY VDE Medium voltage cable for power stations, industrial applications and distribution networks. | Cu | 2 | 6/10 kV | | 90 °C | flame retardent |
NYFGY VDE Armoured medium voltage cable for power stations, industrial applications and distribution networks. | Cu | 2 | 3,6/6 kV | | 70 °C | flame retardent |
NAYFGY VDE Armoured medium voltage cable for power stations, industrial applications and distribution networks. | Alu | 2 | 3,6/6 kV | | 70 °C | flame retardent |
EXeCGB B2ca NBN Halogen-free medium voltage cable with improved fire characteristics. May be used as power supply cable in public networks and industrial plants. | Cu | 2 | 8,7/15 kV | B2ca | 90 °C | low smoke zero halogen fire retardant |
RHZ1 Cca Halogen-free medium voltage cable with improved fire characteristics. May be used as power supply cable in public networks and industrial plants. | Cu | 2 | 6/10 kV, 12/20 kV or 18/30 kV | Cca | 90 °C | low smoke zero halogen fire retardant |
RG26H1M16 Cca 105°C Zero halogen medium voltage cable with improved fire characteristics power stations, industrial applications and distribution networks. | Cu | 2 | 6/10 kV, 12/20 kV or 18/30 kV | Cca | 105 °C | low smoke zero halogen fire retardant |
RE-2Y(St)Y-fl pairs For transmission of analogue and digital signals in instrument and control systems. | Cu | 2 | 500 V | Cca | 70 °C | flame retardent fire retardant |
RE-2Y(St)Y-fl PiMF For transmission of analogue and digital signals in instrument and control systems. | Cu | 2 | 500 V | Cca | 70 °C | flame retardent fire retardant |
RE-2Y(St)YSWAY-fl PiMF For transmission of analogue and digital signals in instrument and control systems. | Cu | 2 | 500 V | Cca | 70 °C | flame retardent |
RE-2Y(St)YSWAY-fl pairs For transmission of analogue and digital signals in instrument and control systems. | Cu | 2 | 500 V | Cca | 70 °C | fire retardant |
RE-2X(St)H PiMF Zero halogen instrumentation cable with improved fire characteristics for transmission of analogue and digital signals in instrument and control systems. | Cu | 2 | 300 V | Cca, B2ca | 90 °C | low smoke zero halogen fire retardant |
H05BQ-F PUR sheathed power cable 450/750V Oil and abrasion resistant use with handheld equipment or building machines. | Cu | 5 | 300/500 V | Eca | 90 °C | flame retardent |
H07BQ-F PUR sheathed power cable. Oil and abrasion resistant use with handheld equipment or building machines. | Cu | 5 | 450/750 V | Eca | 90 °C | flame retardent |
H05V-K Harmonised single core for fixed and protected installation in devices, control cabinets and in or on lighting equipment. | Cu | 5 | 300/500 V | Eca | 70 °C | flame retardent |
H07V-K Harmonised single core for fixed and protected installation in devices, control cabinets and in or on lighting equipment. | Cu | 5 | 450/750 V | Eca | 70 °C | flame retardent |
H07V-R Harmonised single core for fixed and protected installation in devices, control cabinets and in or on lighting equipment. | Cu | 2 | 450/750 V | Eca | 70 °C | flame retardent |
H05Z-K Harmonised, zero halogen single core for internal wiring. | Cu | 5 | 300/500 V | Eca | 90 °C | flame retardent |
H07Z-K Harmonised, zero halogen single core for internal wiring. | Cu | 5 | 450/750 V | Eca | 90 °C | flame retardent |
H07Z-U Harmonised, zero halogen single core with improved fire characteristics for internal wiring. | Cu | 1 | 450/750 V | B2ca, Cca | 70 °C | fire retardant low smoke zero halogen |
H07Z1-R Harmonised, zero halogen single core with improved fire characteristics for internal wiring. | Cu | 2 | 450/750 V | Cca, B2ca | 70 °C | fire retardant low smoke zero halogen |
H07Z1-K Harmonised, zero halogen single core with improved fire characteristics for internal wiring. | Cu | 5 | 450/750 V | Cca, B2ca | 70 °C | fire retardant |
H05V2-K Tri rated Multi-standard, heat resistant single core for internal wiring. | Cu | 5 | 450/750 V | Eca | 90 °C | flame retardent |
H07V2-K Tri rated Multi-standard, heat resistant single core for internal wiring. | Cu | 5 | 450/750 V | Eca | 90 °C | flame retardent |
H07RN-F Rubber-sheated flexible cable. | Cu | 5 | 450/750 V | Eca | 60 °C | flame retardent |
H07RN-F 90°C Premium Rubber-sheathed, flexible cable. | Cu | 5 | 450/750 V | Eca | 90 °C | flame retardent |
H07ZZ-F Zero halogen rubber-sheated flexible cable. | Cu | 5 | 450/750 V | Cca | 90 °C | low smoke zero halogen fire retardant |
NSSHöu Heavy-duty, rubber-sheated flexible cable. | Cu | 5 | 0,6/1 kV | | 90 °C | |
H01N2-D Rubber-sheated flexible arc welding cable. | Cu | 6 | 100 V | | 85 °C | flame retardent |
NSGAFöu Rubber-sheated flexible cable. | Cu | 5 | 1,8/3 kV | Eca | 90 °C | flame retardent |